Over 10 years we help companies reach their financial and branding goals. Engitech is a values-driven technology agency dedicated.

Gallery

Contacts

411 University St, Seattle, USA

engitech@oceanthemes.net

+1 -800-456-478-23

Drag to rotate • Scroll to zoom
ANALYZER
Multi Gas Analyzer Detecting
Multi Gas Analyzer Detecting in Zone 1
in Zone 1
*

High-precision multi-gas analyzer for hydrogen, methane, and CO₂ detection in ATEX Zone 1 hazardous areas. Designed for refinery process control and pipeline injection monitoring.

Scroll to explore

Multi Gas Analyzer Detecting in Zone 1 delivers Process Control* grade precision

Fast hydrogen detection with high sensitivity
Low power consumption, suitable for embedded systems
Wide operating hydrogen concentration range (and humidity range)
High selectivity against common interfering gases (CH₄, CO₂)
Compact, robust package for industrial environments
Compatible with external digital or analog readout electronics

High-precision multi-gas analyzer for hydrogen, methane, and CO₂ detection in ATEX Zone 1 hazardous areas. Designed for refinery process control and pipeline injection monitoring.

Fast hydrogen detection with high sensitivity

Technical Specifications

Target Gas

Target Gas Hydrogen (H₂), Methane (CH₄), Carbon Dioxide (CO₂)

Detection Range

Detection Range Typical: 0.1 – 99.9 % vol H₂ (We have available wider ​ ranges, contact Fast Sense for other models)
Repeatability < 0.1 %

Auxiliary sensors

Auxiliary Sensors Temperature & Humidity sensor

Sensitivity

Resolution 0.05% of the reading
Response Time (T90) < 30 sec (projected < 3 s)

Environmental Specifications

Operating Temperature 0 °C to +80 °C
Storage Temperature -20 °C to +85 °C
Operating Humidity Up to 95% RH, non-condensing
Pressure Atmospheric pressure (<100 mbar)

Electrical Characteristics

Supply power (Solenoid) 12-28 V (recommended 24 V)
Supply power (4-20mA) 12-28 V (recommended 24 V)
Supply power (Equipment) 12-15 V (recommended 12 V)
Supply power (Mudbus) 12-28 V (recommended 24 V)

Power Consumption

Average < 0.6 W
Peak < 1.2 W

Fast hydrogen detection with high sensitivity

Fast hydrogen detection with high sensitivity
Low power consumption, suitable for embedded systems

Low power consumption, suitable for embedded systems

Wide operating hydrogen concentration range (and humidity range)

Wide operating hydrogen concentration range (and humidity range)
High selectivity against common interfering gases (CH₄, CO₂)

High selectivity against common interfering gases (CH₄, CO₂)

Compact, robust package for industrial environments

Compact, robust package for industrial environments
Compatible with external digital or analog readout electronics

Compatible with external digital or analog readout electronics

Engineered for precision

*

Built from deep research and field expertise to deliver the accuracy and reliability your operations demand.

ANALYZER Technology

Designed for Process Control*, Pipeline Injection, Electrolyzers applications. Delivering reliable performance even in the most demanding environments.

Process Control Pipeline Injection Electrolyzers Transformers

Ready to
configure?

System Configuration

Select your required specifications to configure this production unit

System Configuration

Configure your unit specifications below

Configuration Summary

Select options above to see your configuration summary.

High-precision multi-gas analyzer for hydrogen, methane, and CO₂ detection in ATEX Zone 1 hazardous areas. Designed for refinery process control and pipeline injection monitoring.